Vibration control of flexible structures with close modes using adaptive inverse control method
WANG Yong; YAO Tai-ke; CHEN Guang
1. Automation Department, University of Science and Technology of China, Anhui Hefei, 230027;2. Beijing Aerospace Times Laser Inertial Technology Company, Ltd, Beijing, 100143
Abstract:The vibration control of space flexible structures is difficult due to that they are with close models and that the structures parameters can be easily influenced by the complex space environment. That is valuable to study the adaptive inverse control. Multi-variable adaptive inverse control is successfully applied to a 2-D flexible plate test system with close modes, and good experiment results are obtained. Persistent disturbances are suppressed effectively. When the structure parameters change, the procedure of online identification and controller adaptation starts and effective vibration suppression is realized again.
收稿日期: 1900-01-01
通讯作者:
王永
引用本文:
王永;姚太克;陈光;. 密集模态挠性结构振动的自适应逆控制[J]. , 2011, 30(10): 73-76,9.