Experimental investigation on the buffer performance of autoclaved aerated concrete under the impact load of drop weight
ZHOU Yao1, YU Bin1, Guo Quanquan1, Ma Ying2
1.School of Transportation Science and Engineering, Beihang University, Beijing 100191,China;
2. China Nuclear Power Engineering Co. Ltd, Beijing 100191, China
Abstract:The influences of the thickness of specimens and the drop height on the maximun impact force were investigated in impact tests of autoclaved aerated concrete.The test results show that the maximun impact force under a certain impact energy first reduces, then increases as the thickness increases. There is an optimum thickness to minimize the impact force. The formula for calculating the maximun impact force was proposed, by which the calculating results are in good agreement with the test results and the optimum thickness can be derived. During the impact process, the impact energy is converted into the surface energy of the buffer layer material,this surface energy increases first and then decreases with the increase of thickness, and the buffer effect first becomes better and then becomes worse.
周耀1,俞斌1,郭全全1,马英2. 落锤冲击荷载作用下蒸压加气混凝土的缓冲性能试验研究[J]. 振动与冲击, 2019, 38(22): 79-84.
ZHOU Yao1, YU Bin1, Guo Quanquan1, Ma Ying2. Experimental investigation on the buffer performance of autoclaved aerated concrete under the impact load of drop weight. JOURNAL OF VIBRATION AND SHOCK, 2019, 38(22): 79-84.
[1] WANG Rui, HAN Lin-Hai, ZHAO Xiao-Ling, et al. Experimental behavior of concrete filled double steel tubular (CFDST) members under low velocity drop weight impact[J]. Thin-Walled Structures, 2015 (97): 279–295.
[2] 任晓虎,霍静思,陈柏生. 火灾下钢管混凝土梁落锤冲击试验研究[J]. 振动与冲击,2012,31(20):110-115.
REN Xiao-hu, HUO Jing-si, CHEN Bai-sheng. Anti-impact behavior of concrete-filled steel tubular beams in fire[J]. Journal of Vibration and Shock, 2012, 31(20): 110-115.
[3] 霍静思,任晓虎,肖岩. 标准火灾作用下钢管混凝土短柱落锤动态冲击试验研究[J]. 土木工程学报,2012,45(4):9-20.
HUO Jingsi, REN Xiaohu, XIAO Yan. Impact behavior of concrete-filled steel tubular stub columns under ISO-834 standard fire. China Civil Engineering Journal, 2012, 45(4): 9-20.
[4] 王璞,黄真,周岱等. 碳纤维混杂纤维混凝土抗冲击性能研究[J]. 振动与冲击,2012,31(12):14-18
WANG Pu, HUANG Zhen, ZHOU Dai et al. Impact mechanical properties of concrete reinforced with hybrid carbon fibers[J]. Journal of Vibration and Shock, 2012, 31(12):14-18.
[5] ZHANG Wuman, CHEN Shuhang, ZHANG Ning, et al. Low-velocity flexural impact response of steel fiber reinforced concrete subjected to freeze-thaw cycles in NaCl solution[J]. Construction and Building Materials, 2015, 101: 522-526.
[6] ZHANG Wuman, ZHANG Ning, ZHOU Yao. Effect of flexural impact on freeze-thaw and deicing salt resistance of steel fiber reinforced concrete[J]. Materials and Structures, 2016, 49(12): 5161-5168.
[7] ONOUE Kozo, Hiroki Tamai, Hendro Suseno. Shock-absorbing capability of lightweight concrete utilizing volcanic pumice aggregate[J]. Construction and Building Materials, 2015, (83): 261-274.
[8] 王洪欣,查晓雄,余敏等. 低速冲击下金属面夹芯板性能分析[J]. 振动与冲击,2014,33(10):81-86.
WANG Hong-xin, ZHA Xiao-xiong, YU Min et al. Impact resistance performance of metallic sandwich panels under low velocity impact[J]. Journal of Vibration and Shock, 2012, 31(12): 14-18.
[9] Dey V., Bonakdar A., Mobasher B. Low-velocity flexural impact response of fiber-reinforced aerated concrete[J]. Cement & Concrete Composites, 2014, 49: 100-110.