Abstract:A traditional composite steel plate shear wall is assembled with single concrete slab, which has larger dimensions and is difficult for lifting and transporting.The single concrete slab was replaced by multi-precast concrete slab in this paper, and the composite steel plate shear wall with assembled multi-concrete slab was proposed.Three 1/3 scaled composite steel plate shear wall specimens were made: The composite steel plate shear wall with vertical assembling mode(V-CSPSW), composite steel plate shear wall with horizontal assembling mode(H-CSPSW) and traditional composite steel plate shear wall(CSPSW).The cyclic loading tests on specimens were performed.The failure characteristic, hysteretic behavior, ductility, energy dissipation capability and stiffness degradation were investigated.The test results show that the CSPSW with assembled multi-concrete slab has lower lateral stiffness and energy dissipation capacity, but it can reduce the harmful effects of the additional moment on frame columns that the steel plate generates.The V-CSPSW presents bending-shear failure mode, which is ductile failure.The tearing failure appears in the horizontal gaps that between the precast concrete slabs of the H-CSPSW, it presents obvious shearing failure mode.Comparing the horizontal and vertical assembling modes, the ductility coefficient of V-CSPSW is smaller, but other seismic performance indexes such as the energy dissipation capacity, bearing capacity and stiffness are more superior.
韩启浩,汪大洋,张永山. 考虑多块混凝土板拼装的组合钢板剪力墙抗震性能试验研究[J]. 振动与冲击, 2018, 37(18): 193-200.
HAN Qihao, WANG Dayang, ZHANG Yongshan. Experimental study on the seismic behaviors of composite steel plate shear walls with assembled multi-concrete slab. JOURNAL OF VIBRATION AND SHOCK, 2018, 37(18): 193-200.
[1] JGJ/T 380-2015 钢板剪力墙技术规程[S]. 北京: 中国建筑工业出版社, 2016. (JGJ/T 380-2015 Technical specification for steel plate shear walls[S]. Beijing: China Architecture & Building Press, 2016. (in Chinese)).
[2] Dey S, Bhowmick A K. Seismic performance of composite plate shear walls[J]. Structures, 2016, 6: 59-72.
[3] Rahai A,Hatami F. Evaluation of composite shear wall behavior under cyclic loadings[J]. Journal of Constructional Steel Research, 2009, 65: 1528-1537.
[4] Guo L H, Li R, Rong Q, et al. Cyclic behavior of SPSW and CSPSW in composite frame[J]. Thin Walled Structures, 2012, 51: 39-52
[5] 李国强, 张晓光, 沈祖炎. 钢板外包混凝土剪力墙抗剪滞回性能试验研究[J]. 工业建筑, 1995, 25(6): 32-35. (LI Guoqiang, ZHANG Xiaoguang, SHEN Zuyan. Experimental study on hysteretic behavior of concrete-incased steel plate shear walls[J]. Industrial Construction, 1995, 25(6): 32-35. (in Chinese))
[6] Astaneh-Asl A. Seismic behavior and design of composite steel plate shear walls[R]. Moraga: Structural Steel Educational Council, 2002: 1-49.
[7] Zhao Q H, Astaneh-Asl A. Cyclic behavior of traditional and innovative composite shear wall[J]. Journal of Structural Engineering(ASCE), 2004: 271-283.
[8] 郭彦林, 董全利, 周明, 等. 防屈曲钢板剪力墙滞回性能理论与试验研究[J]. 建筑结构学报, 2009, 30(1): 31-39. (GUO Yanlin, DONG Quanli, ZHOU Ming, et al. Tests and analysis on hysteretic behavior of buckling-restrained steel plate shear wall[J]. Journal of Building Structures, 2009, 30(1): 31-39. (in Chinese))
[9] 郭彦林, 周明, 董全利. 防屈曲钢板剪力墙弹塑性抗剪极限承载力与滞回性能研究[J]. 工程力学, 2009, 26(2): 108-114. (GUO Yanlin, ZHOU Ming, DONG Quanli. Hysterestic behavior of buckling-restrained steel plate shear wall[J]. Journal of Building Structures, 2009, 26(2): 108-114. (in Chinese))
[10] 郭彦林, 周明, 董全利, 等. 三类钢板剪力墙结构试验研究[J]. 建筑结构学报, 2011, 32(1): 17-29. (GUO Yanlin, ZHOU Ming, DONG Quanli, et al. Experimental study on three types of steel plate shear walls under cyclic loading[J]. Journal of Building Structures, 2011, 32(1): 17-29. (in Chinese))
[11] 郭兰慧, 戎芹, 马欣伯, 等. 两边连接钢板-混凝土组合剪力墙抗剪性能试验研究及有限元分析[J]. 建筑结构学报, 2012, 33(6): 59-68. (GUO Lanhui, RONG Qin, MA Xinbo, et al. Experimental and analytical study of composite steel plate shear walls connected to frame beams only [J]. Journal of Building Structures, 2012, 33(6): 59-68. (in Chinese))
[12] 马欣伯. 两边连接钢板剪力墙及组合剪力墙抗震性能研究[D]. 哈尔滨: 哈尔滨工业大学, 2009. (MA Xinbo. Seismic behavior of steel plate shear walls and composite shear walls with two-side connections[D]. Harbin: Harbin Institute of Technology, 2009. (in Chinese))
[13] Guo L H, Rong Q, Ma X B. Analysis of composite steel plate shear walls connected with frame beams only [J]. Structures and Buildings, 2013, 166(9): 507-518
[14] 陆烨, 李国强, 孙飞飞. I形大高宽比屈曲约束钢板剪力墙的试验和理论研究[J]. 土木工程学报, 2011, 44(10): 45-52. (LU Ye, LI Guoqiang, SUN Feifei. Experimental and theoretical study on slim I-shape buckling-restrained steel plate shear walls[J]. China Civil Engineering Journal, 2011, 44(10): 45-52. (in Chinese))
[15] 郭彦林, 董全利, 周明. 防屈曲钢板剪力墙弹性性能及混凝土盖板约束刚度研究[J]. 建筑结构学报, 2009, 30(1): 40-47. (GUO Yanlin, DONG Quanli, ZHOU Ming. Elastic behavior and minimum restraining stiffness of buckling-restrained steel plate shear wall[J]. Journal of Building Structures, 2009, 30(1): 40-47. (in Chinese))
[16] GB/T 228.1-2010 金属材料拉伸试验1部分: 室温试验方法[S]. 北京: 中国标准出版社, 2011. (GB/T 228. 1-2010 Metallic materials: tensile testing: part 1: method of test at room temperature[S]. Beijing: China Standard Press, 2011. (in Chinese))
[17] GB/T 2975-1998 钢及钢产品力学性能试验取样位置及试样制备[S]. 北京: 中国标准出版社, 1999. (GB/T 2975-1998 Steel and steel products: location and preparation of test pieces for mechanical testing[S]. Beijing: China Standards Press, 1999. (in Chinese))
[18] JGJ 101—1996 建筑抗震试验方法规程[S]. 北京: 中国建筑工业出版社, 1997. (JGJ 101-1996 Specification of testing methods for earthquake resistant building[S]. Beijing: China Architecture & Building Press, 1997. (in Chinese)