侧向冲击下中空箱形钢管混凝土叠合柱动力响应的实验与有限元分析
贾志路,王蕊
太原理工大学 建筑与土木工程学院,太原 030024
Tests and finite element analysis for dynamic response of hollow box concrete-encased CFST columns under lateral impact
JIA ZhiLu,WANG Rui
College of Architecture and Civil Engineering, Taiyuan University of Technology, Taiyuan 030024, China
摘要 中空箱形钢管混凝土叠合柱由钢筋混凝土和钢管混凝土组成,为研究其抗冲击性能,利用自主研发的落锤式试验机开展箱形叠合柱抗冲击实验,重点研究了边界条件、冲击高度和轴压比对冲击力时程、跨中位移的影响。此外在实验基础上通过ANSYS/LS-DYNA软件建立了有限元模型,分析了各组件内能分配。实验结果表明:随冲击高度的增加,冲击力时程曲线由两段式发展为三段式,内埋钢管混凝土作用逐渐明显;随边界条件的改变,两端固定时的抗变形能力较两端简支时增强;而轴压比对其动力响应影响不显著;冲击能量较大时,钢管混凝土吸收的能量达到了1/3,抗冲击性明显。
关键词 :
钢管混凝土叠合柱 ,
中空箱形截面 ,
冲击性能 ,
动力响应 ,
有限元分析
Abstract :The hollow box concrete-encased CFST (concrete-filled steel tubular) column consists of reinforced concrete and concrete filled steel tube, drop hammer test machine based on independent research and development carries out the box composite columns impact experiments to study its impact behavior, focusing the effect of boundary conditions, impact height and axial compression ratio on the time history of impact force and midspan displacement. In addition, based on the experiment, a finite element analysis model is developed by ANSYS/LS-DYNA software to analyze energy dissipation of each element. The experimental results show that the time history curve of impact force is developed from two stage to three stage with the increase of impact height, and the effect of encased concrete filled steel tube is gradually obvious; with the boundary conditions changing, the anti-deformation capacity of fixed ends is better than that of supported simply at both ends; and the axial compression ratio has little influence on the dynamic response of the member; When the impact energy is large, the energy absorbed by the steel tube concrete reaches 1/3, and the impact resistance is obvious.
Key words :
Concrete-encased CFST columns
hollow box-section
impact performance
dynamic response
finite element analysis
收稿日期: 2017-11-24
出版日期: 2019-04-28
引用本文:
贾志路,王蕊. 侧向冲击下中空箱形钢管混凝土叠合柱动力响应的实验与有限元分析[J]. 振动与冲击, 2019, 38(9): 166-172.
JIA ZhiLu,WANG Rui. Tests and finite element analysis for dynamic response of hollow box concrete-encased CFST columns under lateral impact. JOURNAL OF VIBRATION AND SHOCK, 2019, 38(9): 166-172.
链接本文:
http://jvs.sjtu.edu.cn/CN/ 或 http://jvs.sjtu.edu.cn/CN/Y2019/V38/I9/166
[1] CECS 188:2005 钢管混凝土叠合柱结构技术规程[S].北京:中国计划出版社,2005.
CECS 188:2005 Technical specification for steel tube-reinforced concrete column structure [S].Beijing:China Planning Press,2005.
[2] 韩林海,陶忠,王文达.现代组合结构和混合结构—试验、理论和方法[M].北京:科学出版社,2009:103-105.
HAN Linhai,TAO Zhong,WANG Wenda.Advanced Composite structures and Mixed structures—Testing,Theory and Design Approach[M].Beijing:Science Press,2009:103-105.
[3] 赵均海,侯玉林,张常光.方形高强钢管混凝土叠合柱轴压极限承载力分析[J].土木建筑与环境工程,2016,38(5):20-26.
ZHAO Junhai,HOU Yulin,ZHANG Changguang.Ultimate bearing capacity of square steel tube-reinforced high strength concrete column under axial compression[J].Journal of Civil,Architectural and Environmental Engineering,2016,38(5):20-26.
[4] 康洪震,钱稼茹.钢管混凝土叠合柱轴压强度试验研究[J].建筑结构学报,2006,36(增刊1):22-25.
KANG Hongzhen,QIAN Jiaru.An experiment study of axial compressive Strength of concrete filled steel tube composite columns[J].Journal of Building Structures,2006,36(Suppl.1):22-25.
[5] 王刚,钱稼茹,林立岩.钢管混凝土叠合构件受弯性能分析[J].工业建筑,2006( 2):68-71.
WANG Gang,QIAN Jiaru,LIN Liyan.Study on bending behavior of steel reinforced concrete members[J].Industrial Construction,2006,36(2):68-71.
[6] 郭全全,赵羽西等.钢管混凝土叠合柱偏心受压性能试验研究[J].建筑结构学报,2013,34(12):103-111.
GUO Quanquan,ZHAO Yuxi et al.Experimental study on eccentric compressive property of steel tube-reinforced concrete columns[J].Journal of Building Structures,2013,34(12):103-111.
[7] 曹万林,惠存,董宏英等.底部加强型矩形截面钢管混凝土叠合柱抗震性能研究[J].世界地震工程,2013,29(3):14-21.
CAO Wanlin,HUI Cun,DONG Hongying et al.Study on seismic behavior of bottom strengthened rectangular steel tube reinforced concrete columns[J].World Earthquake Engineering,2013,29(3):14-21.
[8] 惠存,曹万林,王元清等.底部加强矩形钢管混凝土柱抗震性能优化分析[J].振动与冲击, 2016,35(2);141-145.
HUI Cun,CAO WanLin,WANG Yuanqing et al.Numerical analysis for the seismic performance of bottom strengthened retangular concrete filled steel tube columns[J].Journal of vibration and shock,2016,35(2):141-145.
[9] 候舒兰,韩林海,宋天诣.钢管混凝土叠合柱耐火性能分析[J].工程力学,2014,31(增刊):109-114.
HOU Shulan,HAN Linhai,Song Tian- yi.Analysis on concrete-encased CFST columns under fire[J].Engineering Mechanics,2014,31(Suppl):109-114.
[10] 韩林海,宋天诣.钢-混凝土组合结构抗火设计原理[M].北京:科学出版社, 2012:5-112.
HAN Linhai,SONG Tianyi.Fire safety design theory of steel-concrete composite structures [M].Beijing:Science Press,2012:5-112.
[11] 徐蕾,刘玉彬.钢管混凝土叠合柱耐火性能研究[J].建筑结构学报,2014,35(6):33-41.
XU Lei,LIU Yubin.Research on fire resistance of CFSTRC columns subjected to fire[J].Journal of Building Structures,2014,35(6):33-41.
[12] CECS 188: 2005 钢管混凝土叠合柱结构技术规程[S].北京:中国计划出版社,2005.
CECS 188: 2005 Technical specification for steel tube-reinforced concrete column structure [S].Beijing:China Planning Press,2005.(in Chinese).
[13] 王蕊.钢管混凝土结构构件在侧向撞击下动力响应及其损伤破坏的研究[D].[博士学位论文].太原.2008.
WANG Rui.Study on the dynamic response and damage failure of concrete filled steel tube under lateral impact[D].[the degree of Doctor].Tai Yuan.2008.(in Chinese)
[14] WANG Rui,HAN Linhai,ZHAO Xiaoling,et al.Experimental behavior of concrete filled double steel tubular (CFDST) members under low velocity drop weight impact[J].Thin-Walled Structures. 2015,97:279–295.
[15] 程小卫,李 易,陆新征,闫维明.撞击荷载下钢筋混凝土柱动力响应的数值研究[J].工程力学.2015.32(2):53-63.
CHENG Xiaowei,LI Yi,LU Xinzheng,YAN Weiming.Numerical investigation on Dynamic Reponses of Reinforced concrete columns subjected to impact loading[J].Engineering Mechanics.2015.32(2):53-63.
[16] Hallquist J O.LS-DYNA keyword user’s manual [M].California:Livermore Software Technology Corporation,2012:311―317.
[1]
史艳莉1,2,何佳星2,王文达2,鲜威2,王蕊3. 内配圆钢管的圆钢管混凝土构件耐撞性能分析 [J]. 振动与冲击, 2019, 38(9): 123-132.
[2]
韩中合,侯栋楠,赵建宏,朱霄珣. 轴承供气压力对静压气体轴承-转子系统的临界转速影响的研究 [J]. 振动与冲击, 2019, 38(9): 246-251.
[3]
贾俊博1,2,秦雷1,2,3,,仲超1,王丽坤1,2,3. 基于剪切振动模态的压电复合材料应用于水声换能器的研究 [J]. 振动与冲击, 2019, 38(8): 193-197.
[4]
丁传俊,刘宁,张相炎. 多股簧非线性响应模型及其影响研究 [J]. 振动与冲击, 2019, 38(7): 139-145.
[5]
臧 旭1,2,吴 松2,郭其威2,唐国安1. 空间站柔性太阳电池翼模态分析及基频优化 [J]. 振动与冲击, 2019, 38(7): 246-250.
[6]
杨广栋1,2,王高辉1,2,卢文波1,2,赵小华1,2,严 鹏1,2,陈 明1,2. 地表爆炸荷载作用下大型输水箱涵的毁伤评估及防护效应分析 [J]. 振动与冲击, 2019, 38(5): 28-37.
[7]
刘检华,巩浩,丁晓宇. 振动条件下楔形垫圈的防松性能研究 [J]. 振动与冲击, 2019, 38(5): 38-44.
[8]
曹振,马海英,周军勇,李徽,石雪飞. 集中冲击荷载作用下修正Timoshenko梁剪力动载系数研究 [J]. 振动与冲击, 2019, 38(3): 44-50.
[9]
徐瑀童,左洪福,陆晓华,邵传金,李鑫. 复合材料低速冲击损伤评估数值分析与试验研究 [J]. 振动与冲击, 2019, 38(3): 149-155.
[10]
赵立财,余建星. 隧道穿越防护通道受不同钻爆方式作用下岩体动态回应分析 [J]. 振动与冲击, 2019, 38(2): 211-218.
[11]
李娜娜1 许维炳*1 陈彦江1 闫维明1 苏鹏1. 考虑纵坡影响的曲线梁桥地震碰撞响应试验研究 [J]. 振动与冲击, 2019, 38(13): 19-.
[12]
殷森,赵波,李瑜. 模式转换型纵-扭复合超声振动加工系统的设计 [J]. 振动与冲击, 2019, 38(11): 242-248.
[13]
沈超,钱德玲,朱志鹏,叶潇潇,张恒源. 多向地震作用下土-框筒结构动力响应试验研究与数值模拟 [J]. 振动与冲击, 2019, 38(10): 206-214.
[14]
管青海1,周燕1,李加武2,胡兆同2,刘健新2. 主跨420m人行悬索桥非线性静风稳定影响参数分析 [J]. 振动与冲击, 2018, 37(9): 155-160.
[15]
张骞1,高芒芒2,马莉2,宣言2,李红梅2. 沪通长江大桥引桥车桥耦合振动研究 [J]. 振动与冲击, 2018, 37(7): 132-138.