1. Education Ministry’s key laboratory of structure & Earthquake Engineering, Xi’an University of Arch. & Tech., Xi’an;2.material science and engineering post-doctoral mobile stations, Xi’an University of Arch. & Tech., Xi’an;3. Earthquake Engineering Research & Test Center , Guangzhou University, Guangzhou,510405
Abstract:In the light of the ancient building protecting principle “First protect” and “Repair like the old”, 3 SMA dampers are designed; a protection scheme in the ancient pagoda structure which can improve the earthquake resistance of the pagoda is proposed; shaking table tests are performed on the model structure of pagoda in the cases the SMA dampers is erected or unerected.Test ressults demonstrates that the SMA dampers could fulfill the valid seismic energy dissipation, effectively strengthen the seismic capacity of mosque pagoda structure and is worth further exploiting and extensively applying.
赵祥;王社良;周福霖;黄襄云;赵西成. 基于SMA阻尼器的古塔模型结构振动台试验研究[J]. , 2011, 30(11): 219-223.