地震作用下全浮漂大跨斜拉桥耗能减震控制研究

刘彦辉,谭平,金建敏,周福霖,温留汉.黑沙

振动与冲击 ›› 2015, Vol. 34 ›› Issue (8) : 1-6.

PDF(1995 KB)
PDF(1995 KB)
振动与冲击 ›› 2015, Vol. 34 ›› Issue (8) : 1-6.
论文

地震作用下全浮漂大跨斜拉桥耗能减震控制研究

  • 刘彦辉,谭平,金建敏,周福霖,温留汉.黑沙
作者信息 +

Energy dissipation control for long span cable-stayed bridge adopting floating system under earthquake 

  • LIU Yan-hui, TAN Ping, JIN Jian-min,ZHOU Fu-lin, HEISHA Wen-liu-han
Author information +
文章历史 +

摘要

以某实际全浮漂大跨斜拉桥为研究应用对象,探讨了全浮漂大跨斜拉桥阻尼器的布置原则,考虑桩-土的相互作用,建立了全桥空间有限元分析模型,针对该非比例阻尼体系,通过基于应变能理论的振型阻尼分别考虑上部结构阻尼、下部结构阻尼和阻尼器阻尼,从而实现结构不同部分不同阻尼引入到有限元分析模型。然后进行了粘滞阻尼器参数优化,得到了最优阻尼系数和最优阻尼速度指数,并进行减震效果分析。研究结果表明:采用粘滞阻尼器可有效控制结构的地震响应,主塔顶位移、主梁位移和主塔底弯矩分别减小为普通全浮漂体系的60.4%、56.7% 、71.8%,各个桥墩支座位移减震效果;随着阻尼系数增加和阻尼速度指数的减小,梁端位移、塔顶位移和阻尼器位移减小,主塔墩底弯矩单调减少,当达到阻尼系数增加和阻尼速度指数的减小到一定值时主塔墩底弯矩控制效果基本稳定。

Abstract

The arrangement principle of damper for long span cable-stayed bridge adopting full-floating system is discussed based on one actual long span cable-stayed bridge, and considering the pile-soil interaction, the spatial finite element model of was build. According to modal damping of strain energy theory, the effect of damping of superstructure, substructure and damper was evaluated, so difference damping of difference component can be induced in FEM of bridge. Then, parameter optimization of fluid viscous damper was processed and the optimal damping velocity index and damping coefficient were obtained, at the same time, effect of energy dissipation for response of bridge under earthquake was analyzed. Researched result show the displacement of main tower, displacement of girder, bending moment at the bottom of main tower of bridge adopting viscous dampers is decreased to 60.4%, 56.7%, 71.8% of ordinary bridge adopting floating system respectively. With the increase of damping coefficient and decrease of damping velocity index, displacement of girder, main tower and damper is decreased and bending moment at bottom of main tower is monotone decrease. The control effect of bending moment at bottom of main tower will be unchangeable when the increase of damping coefficient and decrease of damping velocity index receive a certain value.

关键词

斜拉桥 / 地震作用 / 耗能减震 / 浮漂体系 / 粘滞阻尼器

Key words

cable-stayed bridge / earthquake effect / energy dissipation / floating system / fluid viscous damper

引用本文

导出引用
刘彦辉,谭平,金建敏,周福霖,温留汉.黑沙. 地震作用下全浮漂大跨斜拉桥耗能减震控制研究[J]. 振动与冲击, 2015, 34(8): 1-6
LIU Yan-hui, TAN Ping, JIN Jian-min,ZHOU Fu-lin, HEISHA Wen-liu-han. Energy dissipation control for long span cable-stayed bridge adopting floating system under earthquake [J]. Journal of Vibration and Shock, 2015, 34(8): 1-6

参考文献

[1] 范立础.桥梁抗震[M].上海:同济大学出版社,1997.
Fan Lichu. Seismic Design for Bridge[M]. Shanghai: Tongji University Press, 1997.
[2] Kim, J., Choi, H., Min, K.W. Performance-Based Design of Added Viscous Dampers using Capacity Spectrum Method [J]. Journal of Earthquake Engineering, 2003, 7(1): 1–24.
[3] Singh, M.P., Verma, N.P., Moreschi, L.M. Seismic Analysis and Design with Maxwell Dampers [J]. Journal of Engineering Mechanics, 2003,129(3):273–282..
[4] Li, B., Liang, X-W. Design of Supplemental Viscous Dampers in Inelastic SDOF System Based on Improved Capacity Spectrum Method [J]. Structural Engineering and Mechanics, 2007, 27(5):541–54.
[5] Pekcan G., Mander J.B., Chen S.S. Fundamental Considerations for the Design of Non-Linear Viscous Dampers[J]. Earthquake Engineering and Structural Dynamics, 1999, 28(11):1405 – 1425.
[6] Lin W-H., Chopra A.K. Earthquake Response of Elastic SDF Systems with Non-Linear Fluid Viscous Dampers[J]. Earthquake Engineering and Structural Dynamics, 2002,31 (9):1623 – 1642.
[7] Hui Li, Jinlong Liu,Jinping Ou. Seismic response control of a cable-stayed bridge using negative stiffness dampers [J]. STRUCTURAL CONTROL AND HEALTH MONITORING, 2011,18:265–288.
[8] 叶爱君,胡世德,范立础. 超大跨度斜拉桥的地震位移控制[J].土木工程学报,2004,37(12):38-43.
Seismic Displacement Control for Super-long-span Cable-stayed Bridges [J]. China Civil Engineering Journal, 2004, 37(12):38-43.
[9] 亓兴军,李小军.大跨飘浮体系斜拉桥减震控制研究[J].振动与冲击, 2007,26(3):85-88.
Qi Xingjun, Li Xiaojun. Study on seismic response control for a long-span floating cable-stayed bridge [J]. Journal of Vibration and shock, 2007,26(3):85-88.
[10] 陈永祁,耿瑞琦,马良喆.桥梁用液体黏滞阻尼器的减振设计和类型选择[J].土木工程学报,2007:40(7):55-61.
Chen Yongqi, Geng Ruiqi, Ma Lianzhe. Design and selection of fluid viscous devices for shock control of bridges[J]. China Civil Engineering Journal,2007:40(7): 55-61.
[11] 陈永祁,杜义新.液体黏滞阻尼器在结构工程中的最新进展[J].工程抗震与加固改造, 2006,28(3): 65- 72.
Chen Yongqi,Du Yixin.Latest development of the fluid viscous damper in civil engineering[J].Earthquake Resistant Engineering and Retrofitting, 2006,28(3): 65- 72.
[12]  建設省道路橋の免震設計法マニュアル案[s]. 1992.
Design method of isolation bridge in Japan[s]. 1992.

PDF(1995 KB)

1451

Accesses

0

Citation

Detail

段落导航
相关文章

/