摘要

考虑了阻尼器中斜坡面反力对位移相关摩擦阻尼器输出力的贡献,从而完善了阻尼器的力学模型,并以一个典型的5层剪切型结构为例,评估了位移相关摩擦阻尼器对橡胶基础隔震结构抗震性能的影响。数值分析表明,位移相关摩擦阻尼器能减小常规地震作用下隔震层的位移响应,但是会增加隔震结构的底层剪力和顶层加速度;在近断层脉冲型地震波作用下,阻尼器能够显著降低隔震层位移,同时对上部结构的地震响应也有较好的抑制作用。此外,位移相关摩擦阻尼器的弹簧初始位移、弹簧刚度和楔块坡面角度这三个参数对隔震结构抗震性能的影响也进行了分析。

Abstract

A mechanical model of displacement dependent friction damper was improved by considering the contribution of slope reaction to output force generated by the damper. Then, taking a five-storey base isolated structure as an example, the influence of the damper on seismic-resistant behavior of base isolated structure with lead rubber bearings was evaluated. Numerical analysis showed that the friction damper could effectively reduce the displacement of isolation floor while increase the base shear force and the top floor acceleration of main structure under normal seismic excitation. When the building subjected to the near-fault pulse-type earthquake, the displacement of isolation floor was significantly reduced and to some extend the seismic response of the main structure was also suppressed. In addition, the influence of three main parameters determining mechanical property of the displacement depended friction damper, that is, initial displacement and stiffness of spring as well as slope angle, on seismic response of the isolated structure was also investigated.

关键词

位移相关摩擦阻尼器 / 基础隔震 / 近断层脉冲型地震 / 常规地震 / 地震反应

Key words

displacement dependent friction damper / base isolation / near-fault pulse-type seismic / normal earthquake / seismic response

引用本文

导出引用
周强,姜文,刘肖. 位移相关摩擦阻尼器基础隔震结构地震响应分析[J]. 振动与冲击, 2016, 35(22): 204-208
Zhou Qiang, Jiang Wen, Liu Xiao. Seismic response of base isolated structure with displacement dependent friction dampers[J]. Journal of Vibration and Shock, 2016, 35(22): 204-208

参考文献

[1] Heaton T H, Hall J F, Wald D J, Halling M W. Response of high-rise and base-isolated buildings to a hypothetical Mw 7.0 blind thrust earthquake [J]. Science, 1995, 267(5195): 206-211
[2] Makris N, Chang S P. Effect of viscous, viscoplastic and friction damping on the response of seismic isolated structure [J]. Earthquake Engineering and Structural Dynamics, 2000, 29(1): 85-107
[3] Nagarajaiah S, Sun X. Base isolated FCC building: Impact response in Northridge earthquake [J]. Journal of Structural Engineering ASCE, 2001, 127(9): 1063-1075
[4] 吴波,李惠. 建筑结构被动控制的理论与应用[M]. 哈尔滨:哈尔滨工业大学出版社, 1997
WU Bo, LI Hui. Theory and application of architecture structural passive control [M]. Harbin: Harbin Institute of Technology Press, 1997
[5] 胡卫兵,王骏涛. 压电摩擦阻尼隔震结构地震响应及控制分析[J]. 振动与冲击, 2007, 26(2): 79-83
HU Wei-bing, WANG Jun-tiao. Earthquake response and control analysis of isolation structure with piezoelectric friction damper [J]. Journal of Vibration and Shock, 2007, 26(2): 79-83
[6] Narasimhan S, Nagarajaiah S. Smart base isolated buildings with variable friction systems: H controller and SAIVF device [J]. Earthquake Engineering and Structural Dynamics, 2006, 35: 921-942
[7] Nims D K, Richter P J, Bachman R E. The use of the energy dissipating restraint for seismic hazard mitigation [J]. Earthquake Spectra, 1993, 9: 467-489
[8] 彭凌云,周锡元,闫维明. 管式变摩擦阻尼器的减振性能试验与数值模拟[J]. 振动与冲击, 2012, 31(5): 12-16
PENG Ling-yun, ZHOU Xi-yuan, YAN Wei-ming. Test and numerical simulation for performance of a tubular type of variable friction damper [J]. Journal of Vibration and Shock, 2012, 31(5): 12-16
[9] 杨庆丽,周强,骆年红. 位移相关摩擦阻尼基础隔震结构地震分析[J]. 西安建筑科技大学学报, 2012, 44(6): 773-778
YANG Qing-li, ZHOU Qiang, LUO Nian-hong. Seismic analysis on base isolated structure with displacement dependent friction damping [J]. Journal of Xi'an University of Architecture and Technology, 2012, 44(6): 773-778
[10] Mostaghel N, Davis T. Representation of Coulomb friction for dynamic analysis [J]. Earthquake Engineering and Structural Dynamics, 1997, 26(5): 541-548
[11] Loh C H, Wan S, Liao W I. Effects of hysteretic model on seismic demands: Consideration of near-fault ground motions [J]. The Structural Design of Tall Building, 2002, 11(3): 155-169

PDF(1228 KB)

630

Accesses

0

Citation

Detail

段落导航
相关文章

/