脉动风激励下格构式输电塔动力特征识别

杨风利1,张宏杰1,杨靖波2,华旭刚3,温青3,牛华伟3

振动与冲击 ›› 2017, Vol. 36 ›› Issue (21) : 144-149.

PDF(1272 KB)
PDF(1272 KB)
振动与冲击 ›› 2017, Vol. 36 ›› Issue (21) : 144-149.
论文

脉动风激励下格构式输电塔动力特征识别

  • 杨风利1,张宏杰1,杨靖波2,华旭刚3,温青3,牛华伟3
作者信息 +

Identification of Dynamic Properties of a Transmission Line Lattice Tower from Ambient Excitations

  • YANG Fengli,1  ZHANG Hongjie,1  YANG Jingbo,2  HUA Xugang,3  WEN Qin,3  NIU Huawei,3
Author information +
文章历史 +

摘要

准确获得模态特征是输电塔抗风抗震等动力响应分析的关键,其中阻尼参数识别尤为重要。本文以一基85.5m高的输电塔为背景,对输电塔的动力特性参数识别进行了研究。根据脉动风作用下实测加速度响应特征,假设信号分段平稳,采用随机子空间法识别了该塔的频率和阻尼比特征。研究结果表明:该输电塔一阶横线向和顺线向模态阻尼比大于2%,而一阶扭转模态阻尼比仅为1%;在加速度不高于0.1m/s2的小振幅振动范围内,阻尼比基本上与振幅无关,识别结果为小振幅下的结构固有阻尼。

Abstract

Accurate determination of modal parameters is crucial to predict the dynamic responses of transmission towers due to wind and seismic excitation, in particular the damping ratio. In this study, the frequencies and damping ratios of an 85.5m-high transmission line tower are identified. Based on the field measured data, the acceleration is assumed to stationary. And the first cross-line mode, along-line mode and torsional mode are estimated by stochastic subspace identification (SSI) from the field testing data. The results indicate that: the damping ratio is slightly larger than 2% for the first cross-line mode and along-line mode and is about 1% for the first torsional mode; the frequencies and damping ratios have little connection with the small vibration amplitudes when the acceleration is not higher than 0.1m/s2, which are can be regarded as the structural damping inherent to the structure.

关键词

输电塔 / 频率 / 阻尼比 / 随机子空间法

Key words

Transmission tower / Frequency / Damping ratio / Stochastic subspace identification

引用本文

导出引用
杨风利1,张宏杰1,杨靖波2,华旭刚3,温青3,牛华伟3. 脉动风激励下格构式输电塔动力特征识别[J]. 振动与冲击, 2017, 36(21): 144-149
YANG Fengli,1 ZHANG Hongjie,1 YANG Jingbo,2 HUA Xugang,3 WEN Qin,3 NIU Huawei,3. Identification of Dynamic Properties of a Transmission Line Lattice Tower from Ambient Excitations[J]. Journal of Vibration and Shock, 2017, 36(21): 144-149

参考文献

[1] ASCE Task Committee (2009), Guidelines for Electrical Transmission Line Structural Loading, Wong C.J. and Miller M.D. (editor), 113-118. American Society of Civil Engineers, New York.
[2] Loredo-Souzaa A.M. and Davenport A.G. (2003), The influence of design methodology in the response of transmission towers to wind loading, Journal of Wind Engineering and Industrial Aerodynamics, 91: 995-1005
[3] BS-8100-1 (1986), Lattice Towers and Masts, Part 1-Code of Practice for Loading, British Standard Institute, London.
[4] Madugula K.S. (2002), Dynamic Response of Lattice Towers and Guyed Masts, American Society of Civil Engineers, New York.
[5] 汪江,杜晓峰,田万军,韩晓林,郑万泔. 500kV淮蚌线淮河大跨越输电塔振动测试与模态识别[J]. 中国电力, 2009, 02:30-33.
WANG Jiang, DU Xiao-feng, TIANWan-jun, HAN Xiao-lin, ZHENG Wan-gan. Dynamic testing and modal identification of long-span power transmission tower located in 500kv Huaibeng Line[J]. ELECTRIC POWER, 2009,02:30-33.
[6] 何敏娟,闫祥梅,张益国,马人乐. 两相邻输电塔的同步环境脉动实测试验研究[J]. 振动与冲击, 2009, 11:155-162
HE Min-juan, YAN Xiang-mei, ZHANG Yi-guo, MA Ren-le. Synchronous test study of two agjacent transmission tower undergoing ambient excitation[J]. JOURNAL OF VIBRATION AND SHOCK, 2009,11:155-162
[7] 闫祥梅,何敏娟,马人乐. 高压输电塔同步环境脉动实测分析与对比[J]. 振动与冲击, 2010, 03:77-80.
YAN Xiang-mei, HE Min-juan, MA Ren-le. Full-scal measurement of ambient vibration around two adjacent transmission towers[J]. JOURNAL OF VIBRATION AND SHOCK, 2010,03:77-80.
[8] 吴毅江,王干军,陈波,郭栩文,王年孝. 基于NExT的转角输电塔自振频率实测研究[J].武汉理工大学学报, 2014, 07:102-107.
WU Yi-jiang, WANG Gan-jun, CHEN Bo, GUO Xu-wen, WANG Nian-xiao. Identification Natural Frequencies of Transmission Angle-tower Based on NExT Through Field Measurement[J]. JOUNAL OF WUHAN UNIVERSITY OF TECHNOLOGY,2014,07:102-107.
[9] 胡宇滨,马人乐. 江阴500kV输电塔动力性能测试[J]. 结构工程师, 2002, 03:62-66.
HU Yubin, MA Renle. Site Experiment of Dynamic Behavior for Jiangyin 500kV Transmission Tower[J]. St ructural Engineers,2002,03:62-66.
[10] 曹枚根,徐忠根,刘智勇,田宝柱. 振动模态识别技术在输电塔线动力特性研究中的应用[J]. 电力建设, 2006, 11:22-25+28.
CAO Mei- gen, XU Zhong- gen, LIU Zhi- yong, TIAN Bao- zhu. Application of Vibration Modal Identification in Dynamic Characteristics Research of Transmission Tower and Conductor[J]. Electric Power Construction, 2006,11:22-25+28.
[11]邓洪洲,司瑞娟,段成荫,等.输电塔气动力系数和气动导纳风洞试验研究[J].振动与冲击,2015,34(3):188-195.
DENG Hong-zhou,SI Rui-juan,DUAN Cheng-meng,et al.Wind tunnel test for aerodynamic coefficient and aerodynamic admittance of a transmission tower[J].Journal of Vibration and Shock,2015,34(3):188-195.
[12] 沈国辉,项国通,邢月龙,郭勇,孙炳楠. 基于EEMD分解的输电塔阻尼特性识别[J].振动与冲击, 2014, 21:38-43+50.
SHEN Guo- hui, XIANG Guo- tong, XING Yue- long, GUO Yong, SUN Bing- nan. Identification of damping characteristics of transmission towers using EEMD[J]. JOURNAL OF VIBRATION AND SHOCK, 2014,21:38-43+50.
[13] 段成荫,邓洪洲. 基于特征系统实现算法的输电塔气动阻尼风洞试验研究[J].振动与冲击, 2014,21:131-136.
DUAN Cheng- yin,DENG Hong- zhou. Wind tunnel tests for aerodynamic damping of a transmission tower based on eigensystem realization algorithm[J]. JOURNAL OF VIBRATION AND SHOCK, 2014,21:131-136.
[14] 邹良浩,梁枢果,王述良. 基于气弹模型风洞试验的输电塔气动阻尼研究[J]. 振动.测试与诊断, 2015, 02:268-275+398.
Zou Lianghao, Liang Shuguo, Wang Shuliang. Analysis of Aerop-Dynamic Damping of Transmission Tower Based on Aero-Elastic Model Wind Tunnel[J]. Jounal of Vibration, Measurement & Diagnosis. 2015,02:268-275+398.
[15] 任坤,李正良,肖正直,汪之松. 环境激励下特高压输电塔线体系气动阻尼的识别[J].重庆工学院学报(自然科学版), 2009, 07:64-68.
REN Kun, LI Zheng-liang, XIAO Zheng-zhi, WANG Zhi-song. Aerodynamic Damping Identification of UHV Transmission Line System under Ambient Exciration[J].Jounal of Chongqing University of Technology(Natural Sciense),2009,07:64-68.
[16] 王述良,梁枢果,邹良浩,汪大海. 输电输电线气动阻尼效应的风洞试验研究[J]. 振动与冲击, 2016, 35(20).
WANG Shu-liang, LIANG Shu-guo, ZOU Liang-hao, WANG Da-hai. Investigation on aerodynamic damping effects of transmission conductor by wind tunnel test[J]. JOURNAL OF VIBRATION AND SHOCK, 2016, 35(20).
[17] 常军,孙利民,张启伟. 一种分段平稳随机信号的参数识别方法[J]. 振动与冲击, 2007, 06:17-20.
CHANG Jun, SUN Limin, ZHANG Qiwei. Method to estimated parameters of piece wise stationary stochastic process[J]. JOURNAL OF VIBRATION AND SHOCK,2007,06:17-20.
[18] Van O, P., De M, B. Subspace identification for linear systems: theory, implementation and applications[M]. Dordrecht (Netherlands): Kluwer Academic Publishers; 1996.
[19] 蒋仲铭. 基于随机子空间法的结构损伤识别研究[D].重庆大学,2013.
Jiang Zhongming Structural Damage Identification based on Stochastic Subspace Identification[D]. Chongqing University,2013
[20 ]刘遥. 汉江大跨越输电塔动态安全评估方法研究[D].重庆大学,2009.
Liu Yao. Research on Dynamic Safety Assessment Method of Hanjiang Long Span Transmission Tower[D]. Chongqing University,2009.

PDF(1272 KB)

Accesses

Citation

Detail

段落导航
相关文章

/