冲击应力对电连接器性能影响的仿真研究

骆燕燕1,2,*,武雄伟1,2,田亚超3,刘旭阳4

振动与冲击 ›› 2019, Vol. 38 ›› Issue (18) : 270-276.

PDF(1370 KB)
PDF(1370 KB)
振动与冲击 ›› 2019, Vol. 38 ›› Issue (18) : 270-276.
论文

冲击应力对电连接器性能影响的仿真研究

  • 骆燕燕1,2,*,武雄伟1,2,田亚超3,刘旭阳4
作者信息 +

Simulation study on the effect of impact stress on electrical connector performances

  • LUO Yanyan1,2, WU Xiongwei1,2, TIAN Yachao3, LIU Xuyang4
Author information +
文章历史 +

摘要

冲击应力是影响电连接器接触性能的主要环境因素之一,受到冲击碰撞后可能发生突发性接触失效现象。为探究冲击过程中接触性能参数变化规律,采用ANSYS进行仿真研究,建立动力学模块模拟冲击试验,分析了较高严酷等级下,不同峰值加速度及脉冲持续时间对接触件形变、应力和接触压力的影响,并从能量角度进行了分析。结果表明:相比于峰值加速度,脉冲持续时间对接触性能参数变化的影响显著;受到2ms以内的冲击,电连接器会在冲击初期出现瞬断失效现象;但若超过2ms,冲击的影响程度明显降低。冲击能量的增加会对接触件的应力值和塑性变形区域产生影响,并导致接触件发生塑性形变。冲击能量相同时,冲击脉冲持续时间越短,接触性能参数的变化幅度越大。

Abstract

Impact stress is one of the main environmental factors that affects the contact performances of electrical connectors.The intermittency phenomenon may occur after impact.The changes of the contact performance parameters of the contactors in the electrical connector during impact process were studied by numerical simulation, and a dynamic physical model was established to simulate the real impact test.The effects of different peak acceleration and pulse duration of an impact on the contact deformation, stress and contact force were analyzed.And the results analysis was carried out from the view point of energy.The results show that, compared with the peak acceleration, the duration of pulse has a significant effect on the change of the contact performance parameter, and the change curve has an inflection point when the duration is 2ms.The increase of impact energy will affect the stress value and strain region of the contactors, and may lead to the plastic deformation of the contactors.The impact energy duration has a more significant effect on the contact performance parameters than the impact energy.It can be deduced that when subjected to an impact of less than 2ms, the contact failure phenomenon is likely to happen in electrical connectors.

关键词

电连接器 / 冲击应力 / 有限元分析 / 接触性能 / 冲击能量

Key words

electrical connector / impact stress / finite element analysis / contact performance / Impact energy

引用本文

导出引用
骆燕燕1,2,*,武雄伟1,2,田亚超3,刘旭阳4. 冲击应力对电连接器性能影响的仿真研究[J]. 振动与冲击, 2019, 38(18): 270-276
LUO Yanyan1,2, WU Xiongwei1,2, TIAN Yachao3, LIU Xuyang4. Simulation study on the effect of impact stress on electrical connector performances[J]. Journal of Vibration and Shock, 2019, 38(18): 270-276

参考文献

[1] 任国泰. 电连接器基本知识(1)[J]. 机电元件, 2004, 24(01): 42-45.
REN Guo-tai. Basic knowledge of electrical connector (1)[J]. Electromechanical Components, 2004, 24(01): 42-45.
[2] 杨奋为.航天电连接器质量检验专题讲座 第5讲 航天电连接器的力学性能检验(下)[J].质量与可靠性,2007(06):54-58.
Yang Fen-wei. Lecture fifth on the quality inspection of spaceflight electrical connectors, lecture fifth on mechanical performance test of space electrical connectors (below) [J]. quality and reliability, 2007 (06): 54-58.
[3] 邓锐,魏武.连接器接触瞬断监测技术与方法[J].电子产品可靠性与环境试验,2016,34(05):42-46.
Deng Rui, Wei Wu. Connector contact transient monitoring technology and method [J]. electronic product reliability and environment test, 2016,34 (05): 42-46.
[4] 支宏旭. 综合环境应力下航空电连接器电接触特性的实验研究[D]. 哈尔滨:哈尔滨工业大学, 2015: 15-51.
ZHI Hong-xu. Experimental study of electrical contact characteristics for aviation electrical connector under combined environmental stress[D]. Harbin: Harbin Institute of Technology, 2015: 15-51.
[5] Sawchyn I, Sproles E. Optimizing Force and Geometry Parameters in Design of Reduced Insertion Force Connectors[C]. SAN DIEGO CA: 42nd Electronic Components and Technology, 1992. 273-281.
[6] 陈文华, 崔杰, 潘骏, 等. 航天电连接器振动可靠性试验与分析[J]. 航空学报, 2003, 24(4): 342-345.
CHEN W H, CUI J, PAN J, et al. Reliability test and statistical analysis of electrical connector under vibration stress[J]. Acta Aeronautica et Astronautica Sinica, 2003, 24(4): 342-345 .
[7] 钱萍, 陈文华, 马子魁, 等. 综合应力加速寿命模型验证方法的研究[J]. 机械工程学报, 2010, 46(24): 156-161.
QIAN P, CHEN W H, MA Z K, et al. Research of multiple stresses accelerated life model verification method[J]. Journal of Mechanical Engineering, 2010, 46(24): 156-161.
[8] 陈文华, 高亮, 李星军, 等. 航天电连接器绝缘电阻随真空度和温度变化规律的研究[J]. 中国机械工程, 2011, 22(22): 2727-2732.
CHEN W H, GAO L, LI X J, et al. Insulation resistance variation with vacuum and temperature for aerospace electrical connectors[J]. China Mechanical Engineering, 2011, 22(22): 2727-2732.
[9] JEDRZEJCZYK P, FOUVRY S, CHALANDON P. A fast methodology to quantify electrical contact behaviour under fretting loading conditions[J]. Wear, 2009, 267(9-10): 1731-1740.
[10] REN Y, FENG Q, YE T Y, et al. A novel model of reliability assessment for circular electrical connectors[J]. IEEE Transactions on Components Packaging and Manufacturing Technology, 2015, 5(6): 755-761.
[11] FLOWERS G T, FEI X, BOZACK M J, et al. Vibration thresholds for fretting corrosion in electrical connectors[C]//48th IEEE Holm Conference on Electrical Contacts. Piscataway, NJ: IEEE Press, 2002: 133-159.
[12] Xie Fei, Flowers G T , Chen Chen. Analysis and Prediction of Vibration-Induced Fretting Motion in a Blade/Receptacle Connector Pair[J]. IEEE Transactions on Components and Packaging Technologies, 2009, 32(03): 585-592.
[13] Yasuyuki Ishimaru, Keiji Mashimo, Kyota Susai. Computational Modeling for Fretting Simulation[C] Vancouver CANADA: Proceeding of the 55th IEEI Holm Conference on Electrical Contacts, 2009, 141-146.
[14] 龙慧娟. 振动对汽车电连接器可靠性的影响[D]. 北京:北京邮电大学,2013:15-48.
LONG Hui-juan. Effect of vibration on reliability of vehicle connector[D]. Bei-jing: Beijing University of Posts and Telecommunications, 2013:15-48.
[15] Perrinet, S. Fouvry and O. Alquier, "Application of the Friction Energy Density Approach to Predict Electrical Contact Endurance in a Silver-Plated Coating Subjected to Fretting Wear," 2013 IEEE 59th Holm Conference on Electrical Contacts (Holm 2013), Newport, RI, 2013, pp. 1-10
[16] 骆燕燕,武雄伟,田亚超等. 冲击环境下电连接器接触性能研究[J]. 工程设计学报, 2018, 25(1): 110-117.
LUO Yan-yan,WU Xiong-wei,TIAN Ya-chao et al. Study on the contact performance of electric connector under impact environment[J]. Chinese Journal of Engineering Design, 2018, 25(1): 110-117.
[17] 潘骏. 航天电连接器振动可靠性建模与评估[D]. 杭州:浙江大学,2002.
Pan Jun.Vibration reliability analysis and modeling of aerospace electrical connectors [D] .Hangzhou: Zhejiang University, 2002.
[18] 郭凤仪,陈忠华。电连接理论及其应用技术[M].北京:中国电力出版社,2008:1-26.
GUO Feng-yi,CHEN Zhong-hua. Electric Conne-ction Theory and Its Application Technology[M].Beijing: China Electric Power Press,2008:1-26.
[19] 张冠生,电器理论基础[M].北京:机械工业出版社,1989:145-170.
ZHANG Guan-sheng, Electrical theory foundation[M]. Beijing: China Machine Press, 1989:145-170.
[20] 徐咏梅,王树荣.电工电子产品环境试验 第2部分:试验方法 试验Ea和导则:冲击:GB/T 2423.5-1995[S].北京:中国标准出版社,1996:3-5.
XU Yong-mei, WANG Shu-rong. Environmental testing for electric and electronic products - Part 2: Test methods - Test Ea and Guidance: Shock: GB/T 2423.5-1995[S]. Beijing: China Standards Press, 1996: 3-5.
[21] 国防科学技术工业委员会.耐环境快速分离小圆形电连接器总规范:GJB 101A-1997[S].北京:中国标准出版社,1997: 10-16.
Commission of Science,Technology and Industry for National Defense. General specification for fast separation of small round electrical connectors   for environmental protection: GJB 101A-1997[S]. Beijing: China Standards Press, 1991: 10-16.
[22] 国防科学技术工业委员会.电连接器接触件总规范:GJB1216-1991[S].北京:中国标准出版社,1991:10-16.
Commission of Science,Technology and Industry for National Defense. General specification for electrical connector contacts: GJB1216—1991[S]. Beijing: China Standards Press, 1991: 10-16.
[23] 任万滨,王鹏,马晓明. 微动诱发的触点电接触间歇失效现象研究[J]. 摩擦学学报, 2013, (04): 382-387.
REN Wang-bin,WANG Peng,MA Xiao-ming.Intermittency phenomenon of electrical contacts ind-uced by fretting behavior[J].Tribology, 2013, (04):382-387.
[24] 王建军.电连接器在动态应力环境中接触电阻的变化及电接触瞬断的检测与研究[J].机电元件,2003(02):36-39.
WANG Jian-jun. Detection and study of contact resistance and electrical contact breakup of electrical connector in dynamic stress environment.[J]. Electromechanical Components, 2003(02):36-39.
[25] 中华人民共和国国家质量监督检验检疫总局.电子设备用机电元件基本试验规程及测量方法:GBT 5095.2-1997[S].北京:中国标准出版社,1997:9-13.
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China. Basic test procedures and measuring methods for electromechanical components used in electronic equipment: GBT 5095.2-1997[S]. Beijing: Standards Press of China,1997:9-13.
[26] 彼得.艾伯哈特,胡斌.现代接触动力学[M].南京:东南大学出版社.2003.2.
Peter. Alberhardt, Hu Bin. Modern ontact kinetics [M]. Nanjing: Southeast University Press .2003.2.
[27] 中国人民解放军总装备部. 电连接器试验方法: GJB1217A—2009[S]. 北京: 国防科学技术工业委员会, 2009: 43-49.
PLA General Armament Department. Test methods for electrical connectors: GJB1217A—2009[S]. Beijing: National Defence Science and Technology Industry Committee , 2009: 43-49

PDF(1370 KB)

Accesses

Citation

Detail

段落导航
相关文章

/