在隔震层安装金属屈服阻尼器可以有效控制隔震层在地震下的位移。由于隔震层在地震下产生多向变形,因此要求安装在隔震层中的金属屈服阻尼器需具有多向的变形能力。既往研究表明U型金属屈服阻尼器在面内具有良好的耗能能力,对于提高结构阻尼比,控制隔震结构的位移具有非常显著的作用。然而关于其面外性能的深入研究尚未见报道。本文提出了开槽U型阻尼器以提高其面外性能,并通过拟静力试验考察了阻尼器宽度,高度,以及长度对其面外性能的影响,实验表明合理设计的开槽U型阻尼器具有良好的耗能能力和低周疲劳性能。本文同时采用有限元方法补充了试件的数量,进行了参数分析。根据参数分析的结果提出了开槽型U型金属屈服阻尼器的屈服位移,屈服恢复力设计公式。另一方面,根据虚功原理提出了开槽U型阻尼器的极限恢复力计算公式,并通过试验结果与有限元模型的计算结果校对了该公式的精度和适用范围。
Abstract
Metal dampers installed in base isolation layers are effective to control the displacement of the base isolation layers. The base-isolation layers deform in multiple directions during an earthquake, requiring that the dampers should also have multi-directional deformation capacity. Previous studies suggest that the U-shaped steel dampers have satisfactory deformation and energy dissipation capacities in-plane, and can significantly increase the damping of the structures and control the displacement of the base isolation layers. However, the out-of-plane behaviours of the U-shaped steel dampers are not necessarily satisfactory. To this end, a new slotted U-shaped steel damper is firstly proposed to improve the out-of-plane performances of the U-shaped steel damper. The effects of the damper width, height, and length on the damper performances are investigated through quasi-static tests. The test results suggest that the U-shaped steel damper with appropriate design parameters has satisfactory energy dissipation capacity and low cycle fatigue behaviour. The formulation is accurate for the estimation of the damper strength. Parametric finite element analysis is conducted to supplement the test results. Based on the results of parametric analysis, the formulas for yield displacement and restoring force of the slotted U-shaped damper are derived through regression analysis. The formulation to estimate the dampers ultimate restoring forces is also derived based on the virtual work principle. The accuracies and application conditions of the formulas are investigated according to the results of experiment and numerical analysis.
关键词
开槽U型阻尼器 /
面外性能 /
拟静力试验 /
虚功原理
{{custom_keyword}} /
Key words
Slotted U-shaped steel damper /
out-of-plane behavior /
quasi-static test /
principle of virtual work
{{custom_keyword}} /
{{custom_sec.title}}
{{custom_sec.title}}
{{custom_sec.content}}
参考文献
[1] Pan P et al. Engineering practice of seismic isolation and energy dissipation structures in China [J]. Science China Technological Sciences, 2012, 55(11): 3036-3046.
[2] 潘鹏,曹海韵,齐玉军,潘振华,叶列平,赵世春,徐亚军. 底部薄弱层结构的柱顶隔震加固改造设计[J]. 工程抗震与加固改造,2009,31(06):69-73.
Pan Peng, Cao Haiyun, Qi Yujun, Pan Zhenhua, Ye Lieping, Zhao Shichun, Xu Yajun. Retrofit of Soft First Story Structure Using Seismic Isolation Technology [J]. Earthquake Resistant Engineering and Retrofitting, 2009, 31(06):69-73
[3] 叶列平,陆新征,马千里,程光煜,宋世研,缪志伟,潘鹏. 屈服后刚度对建筑结构地震响应影响的研究[J]. 建筑结构学报,2009, 30(02):17-29.
Ye Lieping, Lu Xinzheng, Ma Qianli, Cheng Guangyu, Song Shiyan, Miu Zhiwei, Pan Peng. nfluence of post-yielding stiffness to seismic response of building structures. Journal of Building Structures. 2009, 30(02):17-29.
[4] Park J G, Otsuka H. Optimal yield level of bilinear seismic isolation devices [J]. Earthquake engineering & structural dynamics, 1999, 28(9): 941-955.
[5] Shoichi Kishiki, Yuta Ohkawara, Satoshi Yamada, Akira Wada. Experimental evaluation of cyclic deformation capacity of u-shaped steel dampers for base-isolated structures. Journal of Structural and Construction Engineering. Vol. 73 (2008) No. 624 P 333-340.
[6] S. Kato, Y.-B. Kim, S Nakazawa, T. Ohya. Simulation of the cyclic behaviour of J-shaped steel hysteresis devices and study on the efficiency for reducing earthquake responses of spatial structures. .Journal of Constructional Steel Research, 61 (2005), pp. 1457–1473.
[7] S. Kato, Y-B Kim .A finite element parametric study on the mechanical properties of J-shaped steel hysteresis devices .Journal of Constructional Steel Research 62 (2006) ,pp.802–811.
[8] Deng K, Pan P, Wang C. Development of crawler steel damper for bridges [J]. Journal of Constructional Steel Research, 2013, 85: 140-150.
[9] 中华人民共和国行业标准。建筑消能减震技术规程,JGJ297-2013。中国建筑工业出版社。2013。
{{custom_fnGroup.title_cn}}
脚注
{{custom_fn.content}}