基于等效磁路法的电磁力发生器单磁路优化设计

李伟1,2,崔俊宁1,2,邹丽敏1,2,汪志胜1,2

振动与冲击 ›› 2023, Vol. 42 ›› Issue (12) : 309-316.

PDF(2010 KB)
PDF(2010 KB)
振动与冲击 ›› 2023, Vol. 42 ›› Issue (12) : 309-316.
论文

基于等效磁路法的电磁力发生器单磁路优化设计

  • 李伟1,2,崔俊宁1,2,邹丽敏1,2,汪志胜1,2
作者信息 +

Single magnetic circuit optimization design of an electromagnetic force generator based on an equivalent magnetic circuit method

  • LI Wei1,2, CUI Junning1,2, ZOU Limin1,2, WANG Zhisheng1,2
Author information +
文章历史 +

摘要

单磁路电磁力发生器在音圈执行器和振动计量等领域具有广泛的应用,其关键是通过合理的结构设计在磁路气隙中产生具有高分布均匀性的强磁场。提出一种基于等效磁路法的电磁力发生器单磁路解析模型及结构优化设计方法,以典型单磁路为研究对象,基于等效磁路原理和集总参数法建立了气隙磁感应强度分布关于结构尺寸的解析理论模型,并采用有限元仿真验证了理论模型的正确性,二者相对误差约为2.5%,且理论计算较有限元仿真可提高约2000倍的计算效率。分析了各结构尺寸对气隙平均磁感应强度及其分布不均匀性的影响,并通过优化设计获得了较优的结构参数。优化分析结果表明:采用本文方法可将气隙平均磁感应强度提升约150%,磁感应强度分布不均匀性减小约29%。

Abstract

The electromagnetic force generators with a single magnetic circuit are in high demand in fields such as voice coil actuators and vibration metrology, where the key is to generate a strong magnetic field with high distribution uniformity in the magnetic circuit air gap through a rational structural design. This paper proposes an analytical modeling and structural design optimization method for the single magnetic circuit of electromagnetic force generator based on the equivalent magnetic circuit. The analytical theoretical model of the air gap magnetic induction intensity distribution with respect to the structure size is established based on the principle of equivalent magnetic circuit and the method of collective parameters, taking a typical single magnetic circuit as the research object. The accuracy of the theoretical model is verified by using finite element simulation, the relative error is about 2.5%, and the theoretical calculation can improve the calculation efficiency by about 2000 times. The influence of structure size on the average magnetic induction intensity of air gap and its distribution unevenness was analyzed, and better structure parameters were obtained by optimizing the design. The optimized analysis results show that the average magnetic induction intensity of the air gap can be increased by about 150%, and the distribution unevenness of magnetic induction intensity can be reduced by about 29% by using the proposed method.

关键词

单磁路 / 气隙 / 理论模型 / 优化设计

Key words

single magnetic circuit / air gap / theoretical model / optimized design

引用本文

导出引用
李伟1,2,崔俊宁1,2,邹丽敏1,2,汪志胜1,2. 基于等效磁路法的电磁力发生器单磁路优化设计[J]. 振动与冲击, 2023, 42(12): 309-316
LI Wei1,2, CUI Junning1,2, ZOU Limin1,2, WANG Zhisheng1,2. Single magnetic circuit optimization design of an electromagnetic force generator based on an equivalent magnetic circuit method[J]. Journal of Vibration and Shock, 2023, 42(12): 309-316

参考文献

[1] Kim J Y, Ahn D. Analysis of high force voice coil motors for magnetic levitation[J]. Actuators, 2020, 9(4): 133.
[2] 党选举,梁卫,姜辉. 基于改进Preisach模型的音圈电机复杂迟滞建模[J]. 振动与冲击, 2012, 31(21): 156-162.
DANG Xuan-ju, LIANG Wei, JIANG Hui. Complex hysteresis modeling for a voice coil motor based on improved preisach model[J]. Journal of Vibration and Shock, 2012, 31(21): 156-162.
[3] Wang X, Yang B T, Zhu Y. Modeling and analysis of a novel rectangular voice coil motor for the 6-DOF fine stage of lithographic equipment[J]. Optik - International Journal for Light and Electron Optics, 2016, 127(4): 2246-2250.
[4] 罗波,李伟鹏,黄海. 基于Stewart平台的大柔性空间桁架结构振动控制[J]. 振动与冲击, 2012, 31(23): 148-153.
LUO Bo, LI Wei-peng, HUANG Hai. Vibration control of a large flexible space truss using a stewart platform manipulator[J]. Journal of Vibration and Shock, 2012, 31(23): 148-153.
[5] He W, Wang C Y, Yu M, et al. Closed-double-magnetic circuit for a long-stroke horizontal electromagnetic vibration exciter[J]. IEEE Transactions on Magnetics, 2013, 49(8): 4865-4872.
[6] 王其政,刘斌,宋文滨.航天事故与动力学环境预示和控制技术研究述评[J]. 环境技术, 1995, (4): 1-6.
WANG Qi-zheng, LIU Bin, SONG Wen-bin. Aerospace failure and survey of prediction and control technique of dynamic environment[J]. Environmental Technology, 1995, (4): 1-6.
[7] Sharma A K, Haridas R N, Patil A V, et al. Bhonsle. Study of ultra low frequency signals (0.01-10 Hz) associated with moderate earthquake occurred in Koyna region using induction type magnetic sensor[J]. Archives of Physics Research, 2012, 3(5): 320-324.
[8] Shimoda T, Kokuyama W, Nozato H. Primary calibration system for digital accelerometers[J]. Metrologia, 2021, 58(4): 045002.
[9] He W, Zhang X F, Wang C Y, et al. A long-stroke horizontal electromagnetic vibrator for ultralow-frequency vibration calibration[J]. Measurement Science & Technology, 2014, 25(8): 085901.
[10] Rana K. Fuzzy control of an electrodynamic shaker for automotive and aerospace vibration testing[J]. Expert Systems with Applications, 2011, 38(9): 11335-11346.
[11] Zhang X F, He W, Wang C Y. Self-sensing waveform control for a low-frequency electromagnetic vibrator[J]. IEEE/ASME Transactions on Mechatronics, 2017, 22: 785–793.
[12] Liang P X, Feng C, Bi Y L, et al. Analytical model and design of spoke-type permanent-magnet machines accounting for saturation and nonlinearity of magnetic bridges[J]. Journal of Magnetism & Magnetic Materials, 2016, 417: 389-396.
[13] Seo J M, Ro A R, Kim R E, et al. Hybrid analysis method considering the axial flux leakage in spoke-type permanent magnet machines[J]. IEEE Transactions on Magnetics, 2020, 56(9): 8200606.
[14] Cui J N, He Z Q, Tan J B. Proposal and analysis of three closed double magnetic circuits to obtain a very long stroke for electrodynamic force generators[J]. Sensors and Actuators A Physical, 2017, 263: 122-130.
[15] Taqavi O, Taghavi N. Development of a mixed solution of maxwell's equations and magnetic equivalent circuit for double-sided axial-flux permanent magnet machines[J]. IEEE Transactions on Magnetics, 2021, 57(4): 8104411.
[16] Tong W M, Wang S, Wu S N, et al. A complete quasi-3-D analytical model of no-load magnetic field of double-sided slotted AFPMMs considering end effect[J]. IEEE Access, 2018, 6: 59557-59566.
[17] Cui J N, Li W, Bian X Y, et al. Rectangular closed double magnetic circuit offering ultra-long stroke for ultra-low-frequency vibration exciter[J]. Applied Sciences, 2020, 10(17): 6118.
[18] Okyay A, Khamesee M B, Erkorkmaz K. Design and optimization of a voice coil actuator for precision motion applications[J]. IEEE Transactions on Magnetics, 2015, 51(6): 1-10.
[19] Li C, Chen Z W. A fast vibration-level adjustment method for low-frequency vibration calibration based on modified filtered-x least mean square algorithm[J]. Measurement and Control, 2020, 53(3-4): 328-338.
[20] 胡天恩,张旭飞,兰媛. 簧片式电磁振动台波形失真特性分析[J]. 振动与冲击, 2021, 40(21): 179-184.
HU Tian-en, ZHANG Xu-fei, LAN Yuan. Analysis of waveform distortion characteristics of reed type electromagnetic vibrator[J]. Journal of Vibration and Shock, 2021, 40(21): 179-184.
[21] Li H F, Li T M. End-effect magnetic field analysis of the halbach array permanent magnet spherical motor[J]. IEEE Transactions on Magnetics, 2018, 54(4): 8202209.
[22] Zhu Z Q, Pang Y, Howe D, et al. Analysis of electromagnetic performance of flux-switching permanent-magnet Machines by nonlinear adaptive lumped parameter magnetic circuit model[J]. IEEE Transactions on Magnetics, 2005, 41(11): 4277-4287.
[23] Roters H C. Electromagnetic devices[M]. New York: Wiley, 1941.
[24] Liu Y, Zhang M, Zhu Y, et al. Optimization of voice coil motor to enhance dynamic response based on an improved magnetic equivalent circuit model[J]. IEEE Transactions on Magnetics, 2011, 47(9): 2247-2251.
[25] Batdorff M A, Lumkes J H. High-fidelity magnetic equivalent circuit model for an axisymmetric electromagnetic actuator[J]. IEEE Transactions on Magnetics, 2009, 45(8): 3064-3072.