Fault Diagnosis of Vibration Fault of Diesel Generator Control Box

Fu Yanshu;Huang Juhua;Zhang Tingfang;Yang Xuechun;He Chenhong

Journal of Vibration and Shock ›› 2010, Vol. 29 ›› Issue (10) : 153-156.

PDF(1334 KB)
PDF(1334 KB)
Journal of Vibration and Shock ›› 2010, Vol. 29 ›› Issue (10) : 153-156.
论文

Fault Diagnosis of Vibration Fault of Diesel Generator Control Box

  • Fu Yanshu; Huang Juhua; Zhang Tingfang; Yang Xuechun; He Chenhong
Author information +
History +

Abstract

Electronic components vibration fault in control box of diesel generator was analyzed by experimental test and numerical simulation. Experimental results show out that the key point vibration amplitude of control box is small when the diesel generator works on its normal rotational speed, there isn’t overload. So the strong vibration which induced fault may happen during diesel generator starting or shutdown. Then finite element model of vibration was established by Ansys to calculate model shape of frequency range in 0~50Hz. Studies show that several modal shape frequencies are in the range of 0~50 Hz, three sympathetic vibration of control box happened and displacements are larger then experimental test. Corresponding accelerations are also much larger then gravity acceleration, maybe induce serious overload. So connecting pins of electronic components may be tore by the overload force. After analyzing, it can be concluded that the anti-overload ability of electronic components must be taken into account.

Key words

diesel generator / electronic components / vibration frequency / overload

Cite this article

Download Citations
Fu Yanshu;Huang Juhua;Zhang Tingfang;Yang Xuechun;He Chenhong. Fault Diagnosis of Vibration Fault of Diesel Generator Control Box[J]. Journal of Vibration and Shock, 2010, 29(10): 153-156
PDF(1334 KB)

3013

Accesses

0

Citation

Detail

Sections
Recommended

/