Analysis and field test on the EXPO culture center using tmd to reduce human-induced vibration

LU Xi-lin;DING Kun;SHI Wei-xing;WENG Da-gen

Journal of Vibration and Shock ›› 2012, Vol. 31 ›› Issue (2) : 32-37,1.

PDF(3020 KB)
PDF(3020 KB)
Journal of Vibration and Shock ›› 2012, Vol. 31 ›› Issue (2) : 32-37,1.
论文

Analysis and field test on the EXPO culture center using tmd to reduce human-induced vibration

  • LU Xi-lin; DING Kun; SHI Wei-xing; WENG Da-gen
Author information +
History +

Abstract

Expo culture center is one of the permanent buildings in Expo 2010 Shanghai. The main structure composes of 36 hoop cantilever steel trusses with different length and inner frames made of rectangle CFST members. The sixth storey steel structure cantilevered floor easily cause human-induced vibration problem. A large amount of analysis and field tests on the Expo culture center which tuned mass dampers were used to reduce human-induced vibration. The results show that the resonance frequencies of each structural axis are between 2.0Hz and 3.5Hz. The vertical vibration of structure is very small and TMD has no influence on reducing vibration when people walk normally in frequency 2.0Hz. When people rapidly walk or run in structural resonance frequency, TMD can reduce structural vertical vibration about 15% effectively. It can be reference for study on serviceability of space structure with long cantilever and human-induced vibration control by using TMD

Key words

Expo culture center / human-induced vibration / serviceability / tuned mass damper

Cite this article

Download Citations
LU Xi-lin;DING Kun;SHI Wei-xing;WENG Da-gen. Analysis and field test on the EXPO culture center using tmd to reduce human-induced vibration[J]. Journal of Vibration and Shock, 2012, 31(2): 32-37,1