Earthquake simulation shaking table test for seismic performance evaluation of primary water accident pump for nuclear

GAO Yong-wu,DAI Jun-wu,JIN Bo,NIE Gui-bo

Journal of Vibration and Shock ›› 2015, Vol. 34 ›› Issue (20) : 174-178.

PDF(2231 KB)
PDF(2231 KB)
Journal of Vibration and Shock ›› 2015, Vol. 34 ›› Issue (20) : 174-178.

Earthquake simulation shaking table test for seismic performance evaluation of primary water accident pump for nuclear

  • GAO Yong-wu,DAI Jun-wu,JIN Bo,NIE Gui-bo#br#
Author information +
History +

Abstract

Primary water accident pump is an important part in the waste heat export of reactor, whose seismic performance will directly affect reactor safety shutdown and exuding of waste heat after the occurrence of major earthquakes. Under the condition of running, primary water accident pump of prototypes from earthquake simulation shaking table test is the most intuitive method to evaluate the seismic performance. This paper selects the steel wire rubber corrugated pipe connection with import and export of water pipe, use sand pile support rubber bellows with flexible constraints. Reasonable simulation of water pump in the process of the test is over load, at the same time primary water accident pump and circulating water tank in the test process of deformation coordination. In this paper, through selecting wire rubber bellows as in and out of the water pipes, use as constraint of rubber hose, sand guarantees the rationality of the boundary conditions in the process of experiment. Five OBE and one SSE earthquake simulation shaking table tests for the Primary Water Accident Pump were performed by using artificial seismic waves as the seismic inputs in normal running. According to time history curves of strain, the maximum structure responses of strain under the input of different artificial seismic waves were obtained ,and the structure was found in elastic state. The results show that the structural integrity and operating function of the Primary water accident pump are not changed during five OBE and one SSE tests; and the performance indexes of the Primary water accident pump remain consistent before and after seismic tests; the seismic performance of the Primary water accident pump can satisfy relevant technical requirements. 
 

Key words

primary water accident pump / integrity / operating / earthquake simulation shaking table test

Cite this article

Download Citations
GAO Yong-wu,DAI Jun-wu,JIN Bo,NIE Gui-bo. Earthquake simulation shaking table test for seismic performance evaluation of primary water accident pump for nuclear[J]. Journal of Vibration and Shock, 2015, 34(20): 174-178

References

[1] 沈德建,吕西林. 地震模拟振动台及模型试验研究进展[J]. 结构工程师,2006,22(6):55-63.
SHEN De-jian,Lü Xi-li. Research advances on simulating earthquake shaking tables and model test[J].Structural Engineers, 2006,22(6):55-63.
[2] 蔡新江,田石柱. 振动台试验方法的研究进展[J].结构工程师,2011,27(增刊):42-46.
CAI Xin-jiang,TIAN Shi-zhu. Research advances of shaking table testing method[J]. Structural Engineers, 2011, 27(Sup): 42- 46.
[3]  HAF J0053, 核设备抗震鉴定试验指南[S].
[4]  GB 50267-1997, 核电厂抗震设计规范[S].
[5] 洪峰,王绍博. 核电站设备的振动台试验[J].地震工程与工程振动,2001,21(3):94-98.
   HONG feng,WANG shao-bo. Shaking table tests of nuclear power station equipment[J].  Earthquake Engering and Engineeing Vibraton,2001, 21(3): 94-98.
[6] 刘凯雁,施卫星,汪洋,等.核电厂消氢风机抗震性能的振动台试验研究[J].核动力工程,2011,32(6):125-128.
LIU Kai-yan, SHI Wei-xing, WANG Yang, et al. Shaking table test study on seismic performance of dehydrogenation fan for nuclear power plants[J].Nuclear Power Engineering, 2011,32(6):125-128.
[7] 李帅.工程结构模态参数辨识与损伤识别方法研究[D].重庆:重庆大学, 2013.
[8] 高永武, 金波, 侯钢领, 等.基于环境激励的ERA方法在网架结构振动测试中的应用研究[J].地震工程与工程振动,2013,33(4):176-182.
GAO Yong-wu,JIN Bo,HOU Gang-ling,et al.Eigen-system realization algorithm used in the modal parameter identification of spacial trusses based on ambient excitation [J]. Earthquake  Engering and Engineeing Vibraton, 2013,
33(4):176-182.
[9] 淡丹辉, 孙利民.结构动力有限元分析的阻尼建模及评价
[J].振动与冲击,2007,26( 2) :121-124.
DAN Dan-hui,SUN Li-min. Damping modeling and evaluation of structural dynamic finite element analysis [J].Journal of Vibration and Shock,2007,26( 2):121-124.
[10] 李小军,侯春林,潘蓉,等.阻尼矩阵选取对核电厂结构地震响应的影响分析[J].振动与冲击,2015,34(1):110-116.
LI Xiao-jun, HOU Chun-lin,PAN Rong,et al.Effect of damping matrix selection on seismic response of nuclear power plant structures[J].Journal of Vibration and Shock, 2015,34(1):110-116.