Algorithm for the breakage of ice-covered quad bundle conductors based on CR method

LU Jiabo1, 2, LIU Xiaohui1, L Zhongbing3, HUANG Zhan1, FAN Li1, WU Haitao4, CHEN Siwei5

Journal of Vibration and Shock ›› 2024, Vol. 43 ›› Issue (22) : 318-325.

PDF(1618 KB)
PDF(1618 KB)
Journal of Vibration and Shock ›› 2024, Vol. 43 ›› Issue (22) : 318-325.

Algorithm for the breakage of ice-covered quad bundle conductors based on CR method

  • LU Jiabo1,2, LIU Xiaohui*1, L Zhongbing3, HUANG Zhan1, FAN Li1, WU Haitao4, CHEN Siwei5
Author information +
History +

Abstract

In order to analyze the disconnection conditions of ice-covered split wires more quickly and accurately, this paper developed a finite element model of beam and rod elements based on the co-rotational method. A finite element implementation method for disconnection of "node failure" was proposed, and the reliability of the method was verified by comparison with experiments. The finite element program was then written in C++ language, and the program was visualized through QT and VTK toolkits. Finally, a three-level ice-coated four-split finite element model was established. Based on this finite element model, the effects of different ice coating thicknesses and different disconnection positions on the tension of the sub-conductors and the bending moment of the spacer rods were studied. The results show that the spacer rod bears additional torque when the sub-conductor breaks, and the maximum tension value of the unbroken conductor occurs near the spacer rod, and the tension decreases along the conductor away from the break point to the normal operating level. In the case of ice coating, the maximum tension of single sub-conductor and twin sub-conductors increases linearly with the ice coating thickness; when three sub-conductors break, all sub-conductors will break; and when all four sub-conductors break, it can be simplified to single sub-conductor. Calculation of conductors. The simulation results in this paper can provide a reference for transmission line design and fault analysis. The proposed wire breakage simulation method can provide a reliable finite element implementation method for the simulation of wire breakage.

Key words

quad bundle conductors / broken conductor / iced-conductor; 

Cite this article

Download Citations
LU Jiabo1, 2, LIU Xiaohui1, L Zhongbing3, HUANG Zhan1, FAN Li1, WU Haitao4, CHEN Siwei5. Algorithm for the breakage of ice-covered quad bundle conductors based on CR method[J]. Journal of Vibration and Shock, 2024, 43(22): 318-325

References

[1] 邹进涛. 纯阳山输电线路覆冰引起倒塔断线事故的思考[J]. 通讯世界, 2019, 11: 311-312.
Zou Jintao. Reflections on tower collapse accidentscaused by ice accretion on the Purity Yangshan transmission line[J].Telecom World, 2019, 11: 311-312.
[2] 李宏男, 吴育炎. 输电线路覆冰脱落动力效应试验研究[J]. 土木工程学报, 2019, 52(5): 35-46.
Li Hongnan,Wu Yuyan,Dalian et al. Experimental study on dynamic responses of transmission lines caused by ice shedding[J]. China Civil Engineering Journal, 2019, 52(05): 35-46, 100.
[3] 刘昌盛, 刘和志, 姜丁尤, 等. 输电线路覆冰舞动研究综述[J]. 科学技术与工程, 2014, 14(24): 156-164.
Liu Changsheng, Liu Hezhi, Jiang Dingyou, et al. Research Overview on Galloping of Iced Transmission Lines[J]. Science Technology and Engineering, 2014, 14(24): 156-164.
[4] Campbell D B. Unbalanced tensions in transmission lines[J]. Journal of the Structural Division, 1970, 96(10): 2189-2207.
[5] Siddiqui F M A, Fleming J F. Broken wire analysis of transmission line systems[J]. Computers & structures, 1984, 18(6): 1077-1085.
[6] Thomas M B, Peyrot A H. Dynamic response of ruptured conductors in transmission lines[J]. IEEE Transactions on Power Apparatus and Systems, 1982 (9): 3022-3027.
[7] Yang F, Zhang Z, Xing H. Dynamic simulation on a broken test of conductors[J]. Procedia Engineering, 2012, 31: 435-440.
[8] 黄燕群, 郝淑英. 覆冰导线断裂对输电塔受力与变形的影响[J]. 天津理工大学学报, 2014, 30(2): 17-21.
Hao Shuying, Huang Yanqun.The impact on transmission tower's load and deformation caused by iced wires breakage[J]. Journal of Tianjin University of Technology, 2014, 30(02): 17-21.
[9] 黄燕群. 覆冰导线断裂对输电塔受力与变形的影响研究[D]. 天津理工大学, 2014.
Huang Yanqun.The Impact on Transmission Tower's Load and Deformation Caused by Iced Wires Breakage[D]. Chinese Master's Theses Full-text Database, 2014.
[10] Yang F L, Yang J B, Zhang Z F, et al. Analysis on the dynamic responses of a prototype line from iced broken conductors[J]. Engineering Failure Analysis, 2014, 39: 108-123.
[11] Rui X, Ji K, Li L, et al. Dynamic response of overhead transmission lines with eccentric ice deposits following shock loads[J]. IEEE Transactions on Power Delivery, 2015, 32(3): 1287-1294.
[12] 夏正春, 李黎, 梁政平, 等. 输电塔在线路断线作用下的动力响应[J]. 振动与冲击, 2007, 26(11): 45-49.
Xia Zhengchun, Li Li, Liang Zhengping ,et al. Dynamic response of transmission tower with ruptured wires [J]. Journal of Vibration and Shock , 2007, (11): 45-49.
[13] 李黎, 夏正春, 江宜城, 等. 输电线断线振荡研究[J]. 工程力学, 2008(06): 165-169.
Li Li, Xia Zhengchun, Jiang Yicheng, et al. Study on Wire Breaking-induced Vibrations of Electric Transmission Line[J].Engineering Mechanics, 2008(06): 165-169.
[14] 李妍, 刘红军, 李正良, 等. 输电塔线体系断线非线性动力分析[J]. 振动与冲击, 2017, 36 (07): 70-79+85.
Li Yan, Liu Hongjun, Li Zhengliang, et al. Nonlinear dynamic analysis for a transmission tower-line system subjected to wire breakage[J]. Journal of Vibration and Shock, 2017, 36(07): 70-79, 85.
[15] 刘凯铭. 大跨越输电塔-线体系脱冰和断线冲击动力响应分析[D]. 山东大学, 2022.
Liu Kaiming. Dynamic Responses of a Long-Span Transmission Tower-Line System Subjected to Ice-shedding and Cable Rupture[D]. Chinese Master's Theses Full-text Database, 2022.
[16] 张瑚, 汪峰, 吕健双, 等. 基于塔线体系的中冰区分裂导线断线响应分析[J]. 科学技术与工程, 2021,21(34): 14590-14597
ZHANG Hu,WANG Feng,Lü Jian-shuang, et al. Analysis of Broken Line Response of Split Conductor in Middle Ice Area Based on Tower Line System[J]. Science Technology and Engineering, 2021, 21(34): 14590-14597.
[17] Battini J M. Co-rotational beam elements in instability problems[D]. KTH, 2002.
[18] Simo J C, Vu-Quoc L. On the dynamics in space of rods undergoing large motions a geometrically exact approach[J]. Computer methods in applied mechanics and engineering, 1988, 66(2): 125-161.
[19] Fekr M R., Mcclure G. Numerical modelling of the dynamic response of ice-shedding on electrical transmission lines[J]. Atmospheric Research, 1998, 46(1-2):1-11.
[20] 张思祥,马芳,陈鹏等. 输电塔线体系断线冲击分析 [J]. 土木与环境工程学报(中英文), 2021, 43 (03): 142-148.
Zhang Sixiang,Ma Fang,Chen Peng, et al. Finite element analysis of the impact on the transmission tower caused by wire breakage[J]. Journal of Civil and Environmental Engineering, 2021, 43(03): 142-148.
PDF(1618 KB)

157

Accesses

0

Citation

Detail

Sections
Recommended

/